Alert Timer Index Configuration

Use the alerts timer index configuration parameters in create_config.py to define timer index values used by CAMEL voice services.

Table 1. Timer Index Configuration Parameters
Parameter Description Default Value
Timer Index Window Size Sets the timer index window size, in seconds, for processing events. The timer index window should be sized to exceed the maximum of all requested time (in seconds) values configured for any voice service by up to 20 seconds.
Note: The requested time property sets the maximum number of seconds granted in an ApplyCharging operation. For more information, see the discussion about voice charging configuration.

create_config.info question: Config:alert:How many seconds do you want the timer index window to span?

57600
Timer Index Resolution in Milliseconds The maximum number of milliseconds for timer index resolution.

create_config.info question: Config:alert:What is the timer index's resolution in milliseconds?

50