Configure Dynamic Meter Properties
Configure dynamic meter properties by defining a key field list consisting of one or more key field definitions.
About this task
You must select Dynamic on the General tab to display the Dynamic tab.
Procedure
- (Optional) In Instance Relative Start Time, enter the relative start time for the dynamic meter instance.
- (Optional) Select the Instance Relative End Unit to specify the relative end of the meter instance.
- (Optional) Enter the Instance Relative End Unit Count.
-
To add a key field, in the Key Fields table:
- Click Add Field.
- In Add Key Field, begin typing the MATRIXX Data Container (MDC) name in Container Name and a drop-down menu of all valid MDC containers displays to select from.
- In Field Name, begin typing the key field name and a drop-down menu of available field names displays to select from. Available fields are determined by the selected MDC.
- Click Add.
- To delete a field, click in that table row.
-
To add an aggregation selector, in the Aggregation Selectors table:
- In Add Selector, click Add Selector.
- Select the aggregation selector, and click Add.
- To delete an aggregation selector, click in that table row.